How Primary Intention Healing Shapes Suture Choice for Clean Wounds

How Primary Intention Healing Shapes Suture Choice for Clean Wounds

Primary intention healing is the direct healing of a wound whose edges are closed together soon after injury, without a bed of granulation tissue forming first. It depends on edges that meet, tissue that is not under tension and no space left for fluid. The suture has to hold that closure until the wound can bear load.

This article sets out what primary intention healing is, what the closure must achieve and how suture choice shapes the result. It compares the materials in the Gexfix range for clean wounds, and it covers the wounds and situations where suture choice is not the deciding factor. It draws on a veterinary wound management review and a one year study of three skin closure methods in dogs.

What Is Primary Intention Healing?

Primary intention healing, also called first intention healing, is healing in which the wound edges are held together until they unite, so the wound closes without a gap to fill. The wound healing stages overlap, with inflammation first, then tissue formation and then remodelling, and the guide to how absorbable sutures work and how long they last sets out how suture strength falls as tissue regains its own. In primary intention healing the first two stages happen across a closed line, not across an open defect.

The wound management proceedings by Eric Monnet describe primary closure as closure performed soon after injury in an animal that is otherwise in good condition. The wound must be less than 6 hours old, with minimal contamination and tissue trauma, and it must be debrided and lavaged thoroughly first. Sharp wounds with a low bacterial load suit this approach best.

Clean Surgical Wounds

A clean surgical incision meets the same conditions, because it is made with a sharp blade under controlled, aseptic circumstances and the tissue is not crushed or contaminated. That is why a surgical closure is the most reliable setting for primary intention healing, and why the closure itself, not the wound, is the variable the surgeon controls.

When Closure Is Delayed or Healing Is Left to Contraction

Monnet describes three other routes. Delayed primary closure is performed 3 to 5 days after injury, with the wound managed medically in the meantime, and it is used for recent wounds with severe contusion, heavy contamination or sharp wounds of several days' duration. A minimal amount of granulation tissue is acceptable at that closure. Secondary closure is performed 5 days or more after injury, once a granulation bed has formed, and Monnet states that it is rarely used.

Second intention healing leaves the wound open to heal by contraction and epithelialisation. It is chosen for extensive soft tissue damage, devitalised edges, severe infection or a large defect, and the cosmetic result is less ideal. A developed granulation bed is therefore a sign that a wound is healing by a different route, not a sign that primary intention healing is under way.

What the Closure Must Achieve

Edge Apposition

Monnet states that primary closure should provide good anatomical apposition of tissue. The edges have to meet, because any gap is a space that the wound must fill by another route. Accurate apposition is a matter of technique first, and the suture is the means of holding it.

Freedom From Tension

Closure should be achieved without tension. Monnet notes that delayed and secondary closures may need flaps, releasing incisions or undermining to reduce it. In the dog study described below, a subcutaneous layer was placed first in every incision, and the authors recommend a subcutaneous layer to reduce tension on the skin closure. Excessive tension is also one of several mechanical causes of reopening, as the article on causes of surgical wound dehiscence in dogs explains.

No Dead Space

Primary closure should leave no space where fluid can collect. Where a space cannot be closed, Monnet notes that a drain may be placed, which he describes in the context of delayed closure. The practical point for suture choice is that each layer of a closure has a job, and the deep layers are as much a part of primary intention healing as the skin line.

How Suture Choice Shapes the Closure

Monnet advises using as little suture material as possible, because suture can harbour bacteria, and he recommends small monofilament absorbable sutures. That advice sets the starting point. The questions that remain are how the structure of the suture affects the wound, how long it holds and how the skin layer is closed.

Monofilament and Braided Construction

The Gexfix Product Reference describes PGCL MONOFIL® as a monofilament with low tissue reaction and minimal drag, and as the better choice where infection risk exists. It describes ASSUFIL® PGA as a braided, coated suture with excellent handling and knot security that is widely preferred in clean fields, and it warns that braids can wick bacteria, so it advises against use in contaminated or infected wounds. The comparison is set out in the guide to monofilament and multifilament suture in veterinary procedures.

For a clean wound that is closed under good conditions, both constructions are described as suitable in the Product Reference. The difference matters most when conditions are less than ideal, which is the point at which primary closure itself becomes the wrong choice.

Holding Strength and Absorption Time

The Product Reference lists PGA at about 60 to 90 days, PGCL at about 90 to 120 days and PDS at about 180 to 210 days. Those are absorption windows, which are not the same as the period during which a suture holds the wound closed. The Product Reference describes PDS as giving long tensile support and PGCL as giving moderate support duration, and it does not state a holding period in days for any of them. The page on PGCL suture absorption time explains how that figure should be read. A closure carries the load through the early wound healing stages, when the wound has little strength of its own, and the suture has to hold until the tissue can take over. That is why a material is chosen for the period of support the tissue needs and not for its absorption window alone.

Knots and Throws

Each knot is a point where a closure can slip. The Product Reference notes that handling differs between materials. PGCL MONOFIL® is slightly less forgiving than braided PGA, and ASSUFIL® MONOFILAMENTO PDS has a stiffer feel and needs extra throws. A secure knot keeps the edges together as they were placed, which matters in primary intention healing because the apposition set at surgery is the apposition in which the wound heals.

Skin Layer Options

A 2023 study by Balomenos and colleagues, published in Animals, compared three skin closures in 10 healthy Beagles. Each dog had three 12 cm incisions on the lateral thighs, closed with staples, tissue glue or a continuous intradermal suture of 4-0 poliglecaprone 25, which is the polymer class of PGCL. Every incision had a subcutaneous layer of 3-0 polyglactin 910, and the dogs were followed for one year.

Median closure time was 21 seconds for staples, 2 minutes 16 seconds for glue and 15 minutes 37 seconds for the intradermal suture. The intradermal closure had the best overall clinical outcome, and glue produced wider scars than the intradermal closure in three of the five study periods. Total histological scores did not differ significantly between the three methods. The dogs removed four staples in the first 10 days, and one staple wound opened by 0.8 cm on day 10 and healed by second intention. The authors state that staples should be preferred when time matters, such as emergencies, unstable patients or long incisions, and that glue needs careful eversion of the edges and a thin, single layer.

The study compared closure methods, not suture materials, and it used a small group of healthy dogs with thigh incisions in an experimental setting. It shows that the skin method changes the result, and the guide to subcuticular suture technique for veterinary skin closure describes the intradermal approach in more detail.

Comparing Closure Materials for Clean Wounds

The Product Reference does not name primary intention healing as an indication for any suture. The table sets the manufacturer properties of the four materials considered for a clean closure beside what the sources reviewed say about each.

Property

ASSUFIL® PGA

PGCL MONOFIL®

ASSUFIL® MONOFILAMENTO PDS

ASSUNYL®

Structure

Braided, coated

Monofilament

Monofilament

Monofilament, non-absorbable

Absorption time

About 60 to 90 days

About 90 to 120 days

About 180 to 210 days

Permanent

Handling and knot security

Excellent handling and fast, reliable knots

Slightly less forgiving than braided PGA

Stiffer feel; extra throws advised

Not stated in the Product Reference

Infection guidance

Braids can wick bacteria; avoid contaminated or infected wounds

Better choice where infection risk exists

Good in contaminated fields

Low tissue reactivity

Best applications

Routine soft tissue in clean fields

Soft tissue closures needing smooth passage

Fascia, tendons, slow-healing or high-tension tissue

Skin closures and external use; removal needed if not subcuticular

Evidence in the sources reviewed

None

Same polymer class as the poliglecaprone 25 used in the dog study

None

None

The comparison supports a narrow conclusion. Monnet's advice for small monofilament absorbable material matches the properties of PGCL, and a monofilament carries less risk in the conditions where primary closure is least secure. The table does not show that one material produces faster or stronger healing in a clean wound, because none of the sources reviewed tested that. It is reasoning from the manufacturer's figures and from the wound requirements set out above. The guide to choosing suture size based on tissue type and procedure explains how size follows the tissue.

When Suture Choice Is NOT the Deciding Factor

Wounds Unsuited to Primary Closure

No suture can make a wound suitable for primary closure. A wound that is older than 6 hours, contaminated, heavily contused or contains devitalised tissue does not meet the conditions Monnet sets, and he describes delayed primary closure, secondary closure or second intention healing for those wounds. Closing such a wound early with the best available suture still closes bacteria into the tissue, and the closure fails for biological reasons that suture material cannot change.

Technique and Tension

Monnet states that the goal of wound management is to accelerate healing and not to interfere with it. Apposition, tension and dead space are controlled by technique, and a suture that holds a poorly aligned or tight closure still gives a poor result. When a closure reopens, the result is wound dehiscence, which the Gexfix article on its causes describes as more often the end result of several smaller factors than of one failure. In the dog study, cross scarring was present in all staple closed incisions until about day 16, and the authors call it the main disadvantage of staples, although it fades over time.

Method of Skin Closure

The Balomenos study shows that staples, glue and intradermal suture gave different clinical and cosmetic results from the same incisions. The method of skin closure is a separate decision from the choice of absorbable material in the deep layers, and the guide to how skin staples work in animal surgery covers one of the three options.

Choosing a Suture for Primary Intention Healing

The sources establish the conditions for primary intention healing, which are a clean wound closed soon after injury, with edges that meet, no tension and no dead space. They do not establish that one suture material heals clean wounds faster than another. The reasoned choice is a small monofilament absorbable suture for the deep layers, as Monnet recommends, with PGCL MONOFIL® matching that description. ASSUFIL® PGA suits routine soft tissue in a clean field where handling and knot security matter, ASSUFIL® MONOFILAMENTO PDS suits tissue that needs long support, and ASSUNYL® suits the skin line where removal is planned.

Gexfix International Corp., in partnership with Assut Europe S.P.A., supplies PGCL MONOFIL® monofilament sutures in a range of USP sizes and needle configurations for veterinary practice. The complete absorbable suture range also includes ASSUFIL® PGA, ASSUFIL® MONOFILAMENTO PDS, ASSUCROM® Chromic Catgut and FILBLOC® Barbed Sutures. With over 30 years of manufacturing expertise and ISO 13485-certified production standards, Gexfix provides veterinary practices with the reliable monofilament absorbable sutures and full suture portfolio that consistent outcomes require.

Explore the full range at medicaldevicevet.com.

Sources

Monnet E., Wound management (Proceedings), dvm360 (2011; page updated 2020). Conference proceedings by a board-certified veterinary surgeon. It supports the timing of primary, delayed primary and secondary closure, the conditions for primary closure, and the advice on tension, dead space and suture selection.

Balomenos D.B., Gouletsou P.G., Galatos A.D., Evaluation of Incisional Wound Healing in Dogs after Closure with Staples or Tissue Glue and Comparison to Intradermal Suture Pattern, Animals (2023). Peer reviewed a prospective experimental study in 10 Beagles. It supports the closure times, clinical and cosmetic findings, complications and the authors' recommendations.

FAQs

Q. What is primary intention healing and how does suture choice affect it?

A: Primary intention healing is the direct healing of a wound closed edge to edge soon after injury, without a granulation bed forming first. Suture choice affects it because the suture holds the closure while the wound gains strength. The sources reviewed describe the conditions for this healing but do not show that one suture material heals clean wounds faster than another.

Q. What conditions does a wound need for primary closure?

A: Monnet states that the wound should be less than 6 hours old, with minimal contamination and tissue trauma, and that it must be debrided and lavaged first. The closure should align tissue anatomically, without tension and without dead space. Sharp wounds with a low bacterial load suit it best.

Q. How does primary intention healing differ from healing by second intention?

A: In primary intention healing the edges are closed and unite directly. In second intention healing the wound is left open and closes by contraction and epithelialisation, which suits extensive damage, devitalised edges, severe infection or a large defect. The cosmetic result of second intention healing is less ideal.

Q. Which suture materials suit a clean wound closure?

A: Monnet recommends small monofilament absorbable sutures, and the Product Reference describes PGCL MONOFIL® as a monofilament with low tissue reaction. ASSUFIL® PGA suits routine soft tissue in clean fields, and ASSUNYL® suits skin closures where removal is planned. Neither the Product Reference nor the sources reviewed rank them for clean wounds.

Q. When is primary closure not the right choice?

A: Primary closure is not suited to wounds that are older, contaminated, heavily contused or contain devitalised tissue. Monnet describes delayed primary closure 3 to 5 days after injury for some of these wounds, and second intention healing for others. A suture cannot correct a wound that should not have been closed.

Back to blog